Flow Detection: Flow Detect 1000
|
The Flow Detect 1000 is a high quality, industrial grade instrument that senses flow/no-flow conditions of solids and powders in pneumatic pipelines, gravity chutes and feeders. The solid state sensor unit is virtually unaffected by humidity, ambient light, pressure, vacuum, temperature, noise, electrical signals, non-metallic build-up or dust. The control console is equipped with self-monitoring features, LED readout, and separate time delay adjustments for both flow and no-flow conditions. We're confident you'll find the Flow Detect 1000 to be the right choice for reliable flow detection! Features
|
|
|
Specifications: Remote Sensor Probe FDS1000
|
|
| Enclosure: | Aluminum, Urethane Powder Coat, NEMA 4X |
| Power Requirement: | Provided By FDC1000 Control Console, Low Voltage |
| Operating Temperature: | -22° to +158°F (-30° to +70°C) |
| Process Temperature Max: |
+250°F (+121°C) If Ambient Air Temperature Is Below +150°F (+65°C) |
| Process Seal: | TFE Teflon |
| Process Connection: | 1 ¼" NPT (flush mount with half coupling) |
| Conduit Connection: | ¾" NPT |
| Detection Range: | Up To 10' Depending On Target |
| Interconnect Wiring: | 5 Conductor Cable to FDC1000 Control Console |
| Indicators: |
Green LED - Power Red LED - Loop Current |
| Emission: |
24.125 GHz, Less Than 1mW/cm2 (OSHA limit is 10mW/cm2) |
| Approvals: | Intrinsically Safe When Connected To FDC1000 Control Unit, Class II, Groups E, F & G, FCC Part 15 Certification |
|
Specifications: Control Console FDC1000
|
|
| Enclosure: | 8" x 6" x 4" Fiberglass, NEMA 4X, 12, 13 Flange Mount |
| Power Requirement: |
115 VAC, 60/50 Hz, 5VA |
| Operating Temperature: | -31° to +158°F (-35° to +70°C) |
| Output: | DPDT Dry Contacts, 5A @ 240 VAC, or 30 VDC |
| Indicators: |
Green LED - Power Red LED - Loop Fault Yellow LED - Sense Flow Red LED - Alarm |
| Interconnect Wiring: | 5 Conductor Cable to FDS1000 Sensor, Intrinsically Safe |
| Alarm Fail-Safe: | Switch Selectable FLOW or NO FLOW |
| Time Delay: |
FLOW delay, Single Turn, 0.1 - 15 Seconds NO FLOW delay, Single Turn, 0.1 - 15 Seconds |
| Sensitivity Adjustment: | High/Low Selectable, Single-turn Adjustment |
| Approvals: |
Ordinary Locations, Industrial Control Equipment Intrinsically Safe Output to FDS1000 Sensor |